Diabetes
Continuous Glucose Monitors (CGMs) vs Finger-Prick Testing
18 Aug 2025 • Updated 21 Aug 2025

Monitoring blood glucose isn’t busywork — it’s what keeps you safe and gives you agency. Two tools dominate: the finger‑prick meter and the continuous glucose monitor (CGM). They serve different purposes and, used together, cover each other’s blind spots.
Finger‑Prick Testing (BGM)
What it is: a capillary blood test from the fingertip (or alternate site), giving a single reading.
Strengths
- Accurate “now” value with ISO‑standard meters.
- Low cost and no warm‑up, works anywhere.
- Not affected by most compression or sensor warm‑ups.
Limitations
- No trends or alerts — it’s a snapshot.
- Can miss overnight lows or rapid swings between checks.
Where it shines
- Confirming CGM readings during rapid change.
- Pre‑driving, pre‑exercise, illness/sick days.
- Troubleshooting: “Is my CGM right?” → do a meter check.
Continuous Glucose Monitors (CGMs)
What it is: a small sensor under the skin measuring interstitial glucose every 1–5 minutes, streaming to a phone/reader; many offer alarms.
Strengths
- 24/7 visibility: graphs, trend arrows, time‑in‑range.
- Alerts for highs/lows — especially valuable overnight.
- Enables smarter dosing (pre‑bolus timing), exercise planning, and learning patterns.
Limitations
- Lag vs blood during rapid rises/falls (interstitial fluid delay).
- Warm‑up periods, adhesive issues, occasional sensor failures.
- Cost; availability and subsidy vary by country.
Where it shines
- Preventing severe hypos, spotting patterns, refining basal/bolus strategy.
- Powering AID (automated insulin delivery) with compatible pumps.
CGM vs Meter: How to Combine
Think of CGM as the weather radar (direction + speed), and the meter as looking out the window (ground truth).
- Use CGM day‑to‑day for trends, alerts, and learning.
- Use meter to confirm when:
- Symptoms don’t match CGM.
- Reading changes very fast (double‑arrow up/down).
- First 12–24 h of a new sensor feels “off”.
- Before driving if you’re unsure.
- If high with ketones (or unwell): rely on meter readings and follow your sick‑day plan.
Practical Moves
- Pre‑bolus: aim insulin before the CGM line climbs; faster insulins may shorten the gap.
- Compression lows: unexpected CGM low while lying on the sensor? Sit up, wait, or finger‑prick confirm.
- Sensor adhesion: use over‑patches/skin prep; rotate sites to avoid irritation.
- Data sanity: watch time‑in‑range (TIR), GMI, and coefficient of variation (CV) — not just single numbers.
Safety Notes
- Treat hypos first; debate accuracy later.
- For pump users: if high + ketones, inject correction by pen/syringe and change infusion set.
- Don’t ignore alarms at night; adjust thresholds if they’re too noisy, not off.
Related Guides
- Blood Glucose Testing — How and When to Check
- Insulin Administration — Pens, Syringes, and Pumps
- Emergency Actions — Hypos, Highs, and Ketones
- Understanding HbA1c and Why It Matters
References (plain text)
- ISO 15197 meter accuracy standards; CGM manufacturer guidance (Dexcom, Libre, Guardian); ADA/ISPAD consensus on CGM use, TIR, and sick‑day rules.
- #Type 1 Diabetes